Welcome To BTX Online !   

Petri Pulser


Petri Pulser
Reusable electroporation applicator for 6-well plates or 35 mm petri dishes
Product Item # Price  
Petri Pulser 45-0130   View Price
Login/Register to shop in US only.
All others please Login/Register or contact us for local pricing/quotes.

 

 

Details

The Petri Pulser™ is a reusable electroporation applicator designed to fit into each single well of a 6-well plate or an individual 35 mm diameter petri dish. It consists of 13 gold plated electrodes spaced 2 mm apart. The Petri pulser consists of an electrode assembly embedded in a polyurethane holder with high voltage electrode cables. The thin electrodes are gold plated and designed to maximize the surface area of electroporation. The high voltage cables are connected with a BTX Pulse Generator, and the electrode head inserted into the dish or well containing the sample. An electroporation pulse may then be delivered. The entire applicator may be cleaned with mild detergent, and the electrodes may be sterilized with ethanol and dried with acetone.

GENERAL APPLICATIONS

The Petri Pulser is designed for the electroporation of adherent cells in situ or as an alternative to cuvette electroporation for larger volumes or multiple cell samples. The use of the electrode for the electroporation of adherent cells in situ eliminates the need for trypsinization or mechanical removal of cells from their growth substrate. This eliminates associated problems including low plating efficiencies following electroporation, interruption of cell cycle and interruption of intercellular communication.

MAMMALIAN CELL PROTEIN/DRUG ELECTROINCORPORATION

The Petri Pulser supplements our Petri Dish Electrode designed for 100 mm petri dishes, as the ideal electrode for in situ transfecting DNA into mammalian cells.This electrode has been used for electroincorporation of peptides and proteins in CHO cells and murine bone-marrow derived macrophages.

MAMMALIAN CELL TRANSFECTIONS/GENE THERAPY

The Petri Pulser  is capable of supporting transfection protocols developed for our larger 100 mm Petri Dish Electrode, including protocols for BHK and HUVEC. The electrode itself has been used for the transfection of 3T3-L1, K4 and W2 macrophages, Calu3, Rat adipose cells, SF295 human neuroglioblastoma and Cos 7 cells.

PLANT, YEAST AND BACTERIAL ELECTROPORATION APPLICATIONS

Applications involving plant, yeast and bacterial electroporation may be carried out using the Petri Pulser. Scale up and multiple sample processing.

REQUIRED CABLES

Required for connection to Gemini X2 and ECM 830
45-0088 Female/Female Adapter Set for Banana Plug Cables
45-0217 Banana to Banana Cables, Red and Black, 10 ft
Required for connection to ECM 2001+
45-0088 Female/Female Adapter Set for Banana Plug Cables
45-2057 or 45-2058 ECM 2001+ HV Output Cable, 5 ft or 10 ft length
Required for connection to Legacy ECM 2001
45-0088 Female/Female Adapter Set for Banana Plug Cables
45-0083 Coaxial to Banana Plug Cables, Red and Black, 10 ft

 

USE OF PETRI PULSER ELECTRODES WITH THE GEMINI X2 AND ECM 830 ELECTROPORATION SYSTEMS

In this example, the Gemini X2 generator is connected using the sequence of cables and adapters illustrated below, then connected to the Petri Pulser Electrode. 

+ +
 Gemini X2 System    45-0217 Banana to Banana Cables    45-0088 Female/Female Adapters 
+ Petri Pulser Electrode

 

USE OF PETRI PULSER WITH THE ECM 2001+ ELECTROFUSION & ELECTROPORATION SYSTEM

In this example, the ECM 2001+ generator is connected using the sequence of cables and adapters illustrated below, then connected to the Petri Pulser Electrode. 

+ +
 ECM 2001+ System  

 45-2057 or 45-2058 HV Output Cable

   45-0088 Female/Female Adapters 
Petri Pulser Electrode

 

USE OF PETRI PULSER WITH THE LEGACY ECM 2001 ELECTRO CELL FUSION & ELECTROPORATION SYSTEM

In this example, the Legacy ECM 2001 generator is connected using the sequence of cables and adapters illustrated below, then connected to the Petri Pulser Electrode. 

+ +
 Legacy ECM 2001 System    45-0083 Coaxial Cables    45-0088 Female/Female Adapters 
Petri Pulser Electrode

  

Standard Capabilities  
   Voltage Range:   0 - 300 V 
   Pulse Length Range:   1 µs - 35 ms
   Volume Range:   0.5 - 3.0 ml 
 Physical Characteristics  
   Weight:  6 oz 
   Number of Electrodes:   13 
   Electrode Thickness:   0.5 mm 
   Electrode Material:   Gold Plated 
Generator Compatibility  ECM 399, ECM 630, ECM 830, ECM 2001 and Gemini X2
Pulse Length Range  1 µsec - 35 msec
Voltage Range  0 - 300 V
Volume Range   0.5 - 3.0 ml
Autoclavable  No
Field Type  Homogeneous
Gap Size  2 mm

 

 

  • Mammalian cell transfections
  • Gene therapy
  • Protein or drug delivery
  • Plant and yeast applications