Details
These needle style platinum electrodes are specifically designed for in vivo applications on the most fragile of tissue types, such as brain tissue. In vivo transfection of delicate brain tissue can be difficult to perform with out damage to the tissue. The ultra thin electrode enables pinpoint transfection for greater ease and efficiency in fragile or in accessible tissue. These electrodes are ideal for delivering the electrical pulses directly to oocytes or embryos for nuclear transfer fusion applications. Our L-shaped electrodes are available in 3 mm tip length in order to accommodate the most research needs in small animal models.
INCLUDED ITEMS
Item # | Name | Included Items |
45-0510 | Needle L-Shaped Platinum Electrode Kit, 3 mm | 2 extended L-shaped platinum needles ultra thin electrodes and connecting cables |
45-0509 | Needle L-Shaped Platinum Electrode, 3 mm | 2 needle electrodes L-shaped ultra thin diameter platinum (needs 45-0508 cables) |
REQUIRED CABLES
Required for connection to ECM 830 and Gemini X2 | |
45-0216 | Micrograbber to Banana Plug Connection Cables, 10 ft |
Required for connection to ECM 2001+ | |
45-0216 | Micrograbber to Banana Plug Connection Cables, 10 ft |
45-0088 | Female/Female Adapter Set for Banana Plug Cables |
45-2057 or 45-2058 | HV Output Cable, 5 ft or 10 ft length |
Required for connection to Legacy ECM 2001 | |
45-0216 | Micrograbber to Banana Plug Connection Cables, 10 ft |
45-0088 | Female/Female Adapter Set for Banana Plug Cables |
45-0083 | Coaxial to Banana Plug Cables, Red and Black, 10 ft |
USE OF L-SHAPED PLATINUM NEEDLE ELECTRODES WITH THE GEMINI X2 AND ECM 830 ELECTROPORATION SYSTEMS
In this example, the Gemini X2 generator is connected using the sequence of cables and adapters illustrated below, then connected to the L-Shaped Needle Electrodes.
+ | |||
Gemini X2 System | 45-0216 Micrograbber Cables + L-Shaped Needle Electrodes |
USE OF L-SHAPED PLATINUM NEEDLE ELECTRODES WITH THE ECM 2001+ ELECTROFUSION & ELECTROPORATION SYSTEM
In this example, the ECM 2001+ generator is connected using the sequence of cables and adapters illustrated below, then connected to the L-Shaped Needle Electrodes.
+ | + | + | ||||
ECM 2001+ System | 45-2057 or 45-2058 HV Output Cable | 45-0088 Female/Female Adapters | 45-0216 Micrograbber Cables + L-Shaped Needle Electrodes |
USE OF L-SHAPED PLATINUM NEEDLE ELECTRODES WITH THE LEGACY ECM 2001 ELECTRO CELL FUSION & ELECTROPORATION SYSTEM
In this example, the Legacy ECM 2001 generator is connected to the L-Shaped Needle Electrodes using the sequence of cables and adapters illustrated below.
+ | + | + | ||||
Legacy ECM 2001 System | 45-0083 Coaxial Cables | 45-0088 Female/Female Adapters | 45-0216 Micrograbber Cables + L-Shaped Needle Electrodes |
Generator Compatibility | ECM 830, ECM 2001 |
Voltage Range | 0 to 100 VDC |
Pulse Length Range | 10 µs to 100 ms |
Needle Length | 3 mm |
Electrode Length | 3 mm |
Electrode Material | Platinum |
- Ex-vivo tissues gene or drug delivery
- In-vivo tissues gene or drug delivery
- Nuclear transfer
Item # | Product |
---|---|
45-0204 | Adapter Banana Plug Cables, Red and Black (for use with Tweezertrodes and Adherent Cell Electrode) |