Frequently Asked Questions

 

ELECTROPORATION:
What is electroporation?
Why should I use electroporation?
What is the difference between the square waveform and the exponential decay waveform?
What system should I use for mammalian cell electroporation?
What system should I use for bacteria or yeast electroporation?
Can we transfer settings between square and exponential decay waveforms?
Can I transform bacteria or yeast with a square waveform?
Can I transfect mammalian cells with an exponential decay waveform?
What are the electrical variables effecting electroporation?
What other factors effect electroporation efficiencies?
How do I optimize for increased electroporation efficiencies?
What buffers can be used during electroporation?
The results we get in our lab are not as good as they used to be. Could it be the electroporator?
My electroporator just arced. Isn’t this dangerous?
How do I prevent arcing?
How do I prepare electrocompetant E. coli?

 

ELECTROFUSION:
What is electrofusion?
Why should I use electrofusion?
How does electrofusion compare to PEG?
What kind of cells can be fused with electricity?
How are the cells aligned in electrofusion?
What are the factors effecting electrofusion?
What buffers are used during electrofusion?
BTX offers 2 electrofusion systems, why would I choose one over the other?
What cell density do you recommend?
What ratio of B cells to myeloma cells do you recommend for hybridoma production?
What if I don’t see any cell fusion?

 

CUVETTES:
What are the volumes that I can electroporate with BTX Cuvettes Plus?
Can I use other “brand” cuvettes with my BTX electroporator?
How do I orient the cuvettes in the safety stand?
Can the BTX Cuvettes Plus be autoclaved?
Are BTX Cuvettes Plus reusable?

 

MULTI-WELL ELECTROPORATION: 
What are the HT 25 and HT 96 System?
What are the maximum volumes that I can electroporate in an HT plate?
Will my current generator work with the HT plate handler and plates?
Will the HT systems work with any electroporation generator?
Will the HT systems deliver consistence voltage throughout a column?
How do I remove my sample from a cuvette or HT plate?
Does the HT plate and plate handler electroporate one well at a time?
What happens if an arc occurs in the HT plate?
Do I have to fill the whole HT plate with sample or can I choose to fill only certain columns?
Can I use different volumes in each well?
Should I fill all the wells in a column?
Does the resistance in one column affect the entire plate?
Can the BTX HT plates be autoclaved?
Are BTX HT plates reusable?

 

ENHANCER 3000:
What is the Enhancer 3000 Monitoring System?
Can I use the Enhancer 3000 with any generator?

 

BTX:
Do you offer academic or institutional discounts?
Does BTX offer on site application training?
What does ECM stand for?
What does BTX stand for?
How can I order your product if I am in another country?
Where is BTX located?
What is BTX’s operating hours?

 

RETURNS AND REPAIRS :
How long is the BTX warranty on generators, accessories and electrodes?
If I ordered something in error, can I return it?
What if I ordered a BTX system and it doesn’t work for my application?
My generator is under warranty and I believe it’s malfunctioning. How can I get it repaired?
My generator is not under warranty and I believe it’s malfunctioning. How can I get it repaired?
I dropped my 1 year old generator and it’s not working, does the warranty cover repairs?
Can I send my system in for routine calibration?
How long does a repair take?
Can I receive a loaner system while my generator is being repaired?
I am looking for a service manual. Where can I get one?

 

TECHNICAL ASSISTANCE:
If I email your website for technical help, how long does it take to get a response?
Will BTX provide references if I ask?
I am working with a protocol that references a publication. Can I get a copy?
I am looking for a user’s manual. Where can I get one?

 

ELECTROPORATION:
What is electroporation?
Electroporation is the application of an electrical current across a cell membrane resulting in temporary
“pore” formation enabling the uptake of exogenous molecules found in the medium to either the
cytoplasm (transient transfection) or into the nucleus (stable transfection), thereby transfecting
or transforming the cell.
electroporation-cartoon.png

 

Why should I use electroporation?
This technique has been used to introduce plasmids such as DNA and RNA, (including siRNA) proteins,
carbohydrates, dyes, and virus particles into bacterial, yeast, plant, insect and mammalian cells.
Electroporation provides a highly effective alternative to other methods of transfection/transformation.
Electroporation is very easy, there are no toxic side effects on the cells, the uptake of your molecule
is immediate and yields greater transfection/transformation efficiencies. Electroporation, which is
highly reproducible, can work with much broader cell lines or with difficult to transfect cell lines and
is not limited by the size of the plasmid.

 

What is the difference between the square waveform and the exponential decay waveform?
An exponential decay wave is a waveform that is delivered then exponentially decays. This waveform
is ideal when transforming bacteria and yeast. With the majority of the current being delivered
immediately, the tough cell wall becomes permeable to allow the molecule of interest to enter.
The square wave form differs from the exponential decay in the way it is delivered. The square
wave pulse actually looks like a square. The benefit to this waveform is that it is better accepted
by more delicate cells, such as mammalian cells. The square wave allows a period of homeostasis
to be reached in the cells before the wave is removed. As a result, there is a lower mortality rate
in cells while maintaining transfection efficiencies. While both waveforms are capable of electroporating
bacterial, yeast and mammalian cells, each waveform has its benefits. Exponential decay waves will
result in a higher rate of cell mortality in mammalian cells and square waves will result in lower
transformation efficiencies in bacteria and yeast.

 

What system should I use for mammalian cell electroporation?
BTX offers several square wave systems that are capable of efficiently transfecting mammalian cells.
The ECM 830, ECM 2001, Agile Pulse In Vivo, Agile Pulse MAX and Agile Pulse HT. The system choice
will depend on what types of applications you will be running. The ECM 830 system is a general purpose
mammalian cell electroporation system; it offers the researcher the ability to transfect cells in suspension
in either cuvettes or 96 well plates, to perform in vivo electroporation with specialty electrodes or
adherent cell transfection. The ECM 2001 was designed as a dual wave system and is primarily used
for electrofusion of cells, but can also be used as an electroporator as well. The ECM 2001 offers the
researcher the ability to transfect cells in suspension in cuvettes, to perform in vivo electroporation with
specialty electrodes or adherent cell transfection. The Agile Pulse In Vivo system was designed for in
vivo electroporation applications. It is primarily used for vaccine applications. The Agile Pulse MAX system
is a large volume transfection setup for researchers working with volumes of up to 20ml. The Agile Pulse
HT system is a large volume transfection setup for researchers working with volumes up to 1000ml. Call
BTX sales support for help making a choice.

 

What system should I use for bacteria or yeast electroporation?
In general, we recommend using an exponential decay wave for bacteria transformation. The ECM 630
is the unit of choice to transformation bacteria and yeast. This system offers adjustable capacitance
and resistance settings, the combination of which determines the time constant or time the sample is
exposed to electricity. Because of the flexibility of time constant options, this system is capable of
transforming both gram – and gram + bacteria, yeast, algae and plant cells in either cuvettes or in a
96 well format. BTX also offers the ECM 399 an economic exponential decay wave electroporator for
simple E. coli transformation with a plasmid under 20 Kb.

 

Can we transfer settings between square and exponential decay waveforms?
Yes. Contact BTX Technical Service for a conversion chart that will guide you through the process.
It is easier to convert from exponential decay waves to square waves.

 

Can I transform bacteria or yeast with a square waveform?
Yes. While the square waveform is not optimal for bacterial or yeast transformation, it can still
transform the cells. That being said, the transformation efficiencies will be lower using the square
waveform than with the exponential decay waveform.

 

Can I transfect mammalian cells with an exponential decay waveform?
Yes. While the exponential decay waveform is not optimal for mammalian cell transfection, it can
still transfect the cells. That being said, the viability of the cells will be lower using the exponential
decay waveform than with the square waveform.

 

What are the electrical variables effecting electroporation?
Waveform
effects electroporation, you can choose either square waves, generally for mammalian
cells or exponential decay waves, generally for bacteria and yeast. Please see section of FAQ’s
discussing waveforms. Voltage is the second key to electroporation. The voltage setting indicates
how much voltage your sample will receive, this is also called Field Strength and is measured kV/cm.
The higher the field strength, the better the efficiencies, however with higher field strengths come a
higher cell mortality rate. Pulse Length is the next electrical parameter effecting electroporation.
Pulse length determines how long your sample is exposed to the voltage usually measured in usec,
msec, and sec with a square wave generator. The combinations of Capacitance and Resistance
(used in exponential decay wave generators) settings in conjunction with the resistance of your
sample basically come up with the time constant. Number of Pulses (with the square wave
generators) is the number of times you want your sample exposed to the voltage. You can also
choose a pulse interval for the time between pulses to allow your cells to rest.

 

What other factors effect electroporation efficiencies?
There are many other factors affecting your electroporation besides electrical factors. Cellular
factors
such as growth phase at time of harvesting (should be early to mid log phase) cell density,
cell diameter, cell wall rigidity and susceptibility to electroporation. There are also physiological
factors
such as temperature of cells, osmolarity, DNA or Plasmid concentration, quality of DNA or
Plasmid, ionic concentration of buffer, and post electroporation incubation conditions. Please contact
BTX if you need more assistance in this area.

 

How do I optimize for increased electroporation efficiencies?
Optimization consists of modifying one electroporation variable at a time to reach an optimal
compromise by way of transfection efficiency and viability percentage. The parameters to vary
are field strength kV/cm, pulse length (msec or sec, dictated by the RC value in exponential decay
wave generators), pulse number, and pulse interval. Generally, the field strength is the first
variable to vary when optimizing. Please contact BTX technical service if you require more
assistance in this area.

 

What buffers can be used during electroporation?
Researchers can use buffers with low conductivity and low osmolarity to enlarge cells and facilitate
the breakdown of the membrane. The low conductivity allows users to set a lower voltage. High
conductivity and high osmolarity buffers such as growth media, PBS and sucrose solution cause
fairly high currents in the cuvette which could damage cells. Hypoosmolar buffers creates osmotic
overpressure in the cell during electroporation. This causes water to enter the cell. The cell
enlarges and the membrane expands. This leads to a reduction in the voltage applied.
Furthermore, the swelling of the cell causes the cytoskeleton to break, which leads to the
membrane losing its internal stability. This facilitates the electroporation of the cell and increases
the efficiency of the application.

 

The results we get in our lab are not as good as they used to be. Could it be the electroporator?
Possibly. Our technical group can get you the appropriate tests to evaluate the electroporation
generator you are using. If the instrument is not used for long periods of time, the capacitors in
electroporation generators age and may not have the same output. In these situations, re-optimization
is suggested and can usually be accomplished by varying the voltage slightly. Most reports of an efficiency
decrease may be traced to changing biological parameters or technique. Electroporation is dependent
on temperature, volume, buffer compositions, etc. Thus, it is wise to take a good look at these factors
before exploring equipment failures.

 

My electroporator just arced. Isn't this dangerous?
Arcing is a statistical occurrence and poses no danger to the user. The 630B safety stand will contain
the arc in a closed environment. All BTX generators are "arc-proof" (short-circuit proof in the event of
an arc).

 

How do I prevent arcing?
You cannot "prevent" arcing from happening, but you can minimize the probability of the occurrence
by lowering the voltage or switching to a lower conductivity electroporation media. For bacterial
electro-transformation, be sure to carefully follow washing procedures to remove salts. For ligation
reactions dilute at least 1:5 with water or TE, or use a proven method for desalting before
electroporation. Using only high-quality cuvettes can also reduce the chances of arcing.

 

How do I prepare electrocompetant E coli?
Inoculate 1L of rich broth appropriate for rapid cell growth with 1/10 to 1/100 volume of fresh
overnight culture. Grow cells at the growth temperature and conditions optimal for the strain.
Harvest when cells reach early to mid log phase growth (usually around OD600nm of ~0.5). To
harvest, chill the growth flask on ice for 15-30 minutes, and centrifuge in a cold rotor at 4,000 x g
for 15 minutes. Resuspend the pellets in a total of 1l of cold water. Centrifuge as above. Resuspend
in 0.5l of cold water. Again centrifuge. If cells are to be stored frozen, resuspend in ~20ml of
cryoprotectant (usually 10% glycerol). Cells to be used fresh may be resuspended in water at this
point. Centrifuge as above. Resuspend to a final volume of 2-3 ml in cryoprotectant or water. The
cell concentration should be high. With some species a concentration of up to 5 x 1010 cells/ml is
desirable. At this point, many species may be frozen in 10% glycerol and stored at —70° C for up
to a year with little loss of electrocompetence.

 

  • Guide to Electroporation and Electrofusion, Chang, Chassy, Saunders, and Sowers, pg. 487, Academic Press, copyright 1992.

 

ELECTROFUSION
What is electrofusion?
Electrofusion is a combination of the use of AC alignment, DC square wave electroporation followed 
by post fusion AC alignment.   The first AC Alignment causes the cells to align in pearl chains or
dimes putting the cell membranes in contact then a DC square wave pulse is applied to cause pores
to form in the cells, the third step is to apply a post fusion AC alignment which will keep the newly
fused cells in contact. See diagram below.
electrofusionprocess.jpg

Why should I use electrofusion?

Electrofusion is more efficient than PEG, results are reproducible, reliable, cost effective and
optimized protocols have already been established.

 

How does electrofusion compare to PEG?
Electrofusion is able to facilitate considerably higher hybrid yields for many cell types, up to
80 fold over PEG- mediated fusion. Significantly lower amounts of B cells are required with
electrofusion. Electrofusion is faster, easier to use, more reproducible, more reliable and more
cost effective than PEG. Additionally, electrofusion can be view in real-time under a microscope.

 

What kind of cells can be fused with electricity?
Any cell type can be fused with electrofusion.

 

How are the cells aligned in electrofusion?
An AC waveform is applied to align cells by dielectrophoresis. More specifically, an electric
field induces a dipole within the cell. As cells move towards a common point, the dipoles attract
and pearl-chain formation results.

 

What are the factors effecting electrofusion?
There are many factors effecting electrofusion. Electrical parameters, the condition of the cells
prior fusion, buffer and post fusion cell handling are a few of these factors.  

 

What buffers are used during electrofusion?
We recommend using the Cytofusion buffer for Electrofusion, however many labs prefer to
make their own electrofusion buffer.

 

BTX offers 2 electrofusion systems, why would I choose one over the other?
There are several factors to consider when choosing either the ECM 2001 or the Hybrimune,
the biggest factor being sample volume.   Please read through the product pages to get a
complete understanding about the functionality of each system, however the main differences
between the systems are as follows:

 

 ECM 2001
• Can be used as an electrofusion or electroporation system
• Can perform fusions on samples up to 2 mls or 40 million cells total per fusion
• This system is independently operated and does not require a computer for operation
• There is no annual license fee associated with this system

 The Hybrimune
• Can perform fusions on samples up to 9 mls or 180 million cells total per fusion
• This system is computer controlled
• There is an annual license fee associated with this system through a 3rd party company called Cellectis

What cell densities do you recommend?

We recommend no more than 20 million cells per ML for fusion.

What ratio of B cells to myeloma cells do you recommend for hybridoma production?
We recommend a 1:1 ratio. 
celllinemixture.jpg


What if I don’t see any cell fusion?
While unusual, low or no fusion can happen for a variety of reasons. Keep in mind, electrofusion is sensitive 
to factors that may have not been issues with PEG-fusion such as:
• High current due to high ion content
• Dirty electrode
• Field strength is not high enough
• Contaminated or high conductivity medium
• Inadequate cell wash
• Excessive force applied to cells
• AC amplitude too high
• AC amplitude too long
• Cable connection issues
• Generator issues
Contact our technical service department for help troubleshooting your application.

 

CUVETTES
What are the volumes that I can electroporate with using the BTX Cuvettes Plus?
The maximum sample volume depends on the cuvette size. The maximum samples sizes for the various size
cuvettes are as follows:
 
  • 1 mm gap: 20 to 90 µl Identified easily with a gray cap.
  • 2 mm gap: 40 to 400 µl Identified easily with a blue cap.
  • 4 mm gap: 80 to 800 µl Identified easily with a yellow cap.

 

Can I use other "brand" cuvettes with my BTX electroporator?
Yes, any BTX instrument will accommodate most commercially available electroporation cuvettes.

 

How do I orient the cuvettes in the safety stand?
Each cuvette has a pair of aluminum electrodes, the metallic sides. These sides should face
the metal contacts of the safety stand.  Each cuvette should be wiped down of any condensation
before being placed into the safety stand. Two cuvettes can be electroporated at one time in the
630B safety stand.

 

Can the BTX Cuvettes Plus be autoclaved?
No. The BTX Cuvettes Plus contain a polymer that will melt if autoclaved.

 

Are the BTX Cuvettes Plus reusable?
We do not recommend reusing BTX cuvettes. The small gap size of the cuvettes creates
nooks for salt to build up and if the cuvette is reused, it could cause arcing.

   

MULTI-WELL ELECTROPORATION
What are the HT 25 System and HT 96 Systems?
The HT Systems are a multi-well approach to electroporation in either 25 or 96 wells. These
systems are unique tools developed and patented by BTX, Harvard Apparatus. These systems
are essential to labs looking for any of the following benefits:

 

  • Saving time by optimizing protocols very rapidly,
  • Boosting productivity by varying electrical parameters and also biological parameters
  • Saving money by using less sample volume
  • Less waste product by allowing use of less sample volume
  • Quickly and efficiently screening of entire libraries.

   

What are the maximum volumes that I can electroporate in an HT plate?
The maximum sample volume depends on the HT plates’ gap size. The maximum samples sizes
for the both the 96 well and 25 well HT plates are as follows:

  • 2 mm gap: 20 to 125 µl.
  • 4 mm gap: 40 to 250 µl.

   

Will my current generator work with the HT plate handler and plates?
Currently the HT plate handler and plates are designed to work with ECM 830 and ECM 630
generators.

   

Will the HT systems work with any electroporation generator?
No. The HT system is a very powerful tool and other generators currently available cannot
sustain the voltage and pulsing capabilities that the ECM 830 and the ECM 630 can.

   

Will the HT systems deliver consistent voltage throughout a column?
Yes. The HT Systems deliver consistent voltage throughout a column giving the user
confidence that the correct voltage was delivered to each well.

 

How do I remove my sample from a cuvette or an HT plate?
Initially cells should not be removed to allow them to rest. Cells should be treated carefully
as they are stressed. With each BTX Cuvettes plus, there is a sterile pipette included.
Use this pipette to remove your sample. In the case of the HT 96 well plates, use an
8 channel pipetter to remove the sample.

 

Does the HT plate and plate handler electroporate one well at a time?
No. The plate handlers deliver pulses across the columns of the HT plates.

 

What happens if an arc occurs in the HT plate?
If an arc occurs, it will only affect the cells in the column in which the arc occurred.

 

Do I have to fill the whole HT plate with sample or can I choose to fill only certain columns?
You can choose to use as few as one column or fill the plate. We recommend using the protective
sheets provided with the plates to ensure no cross contamination occurs. However, if you choose
to use only part of the plate, you must ensure that each well in the columns you are using is filled,
even if it’s just buffer.

 

Can I use different volumes in each well?
No. If you fill each well with different volumes, it will effect the overall resistance in that column
and could cause the time constant to vary or even cause an arc.

 

Should I fill all the wells in a column?
Yes. If you choose to use only part of a column, you just fill the remaining wells with the buffer
you are electroporating your sample in. This will ensure the resistance is within the appropriate
range and avoid arcing.

 

Does the resistance in one column affect the entire plate?
No. Each column is independent from one another. If an arc occurs in one column, the remainder
of the plate can be processed as it normally would, given that it does not contain additional arc
conditions within the rest of the columns.

 

Can BTX HT plates be autoclaved?
No. The plate contains a polymer that will melt if autoclaved.

 

Are BTX HT plate reusable?
We do not recommend reusing HT plates. The small gap size of the plates creates nooks for
salt to build up and if the plate is reused, it could cause arcing.

   

ENHANCER 3000 MONITORING SYSTEM
What is the Enhancer 3000 Monitoring System?
The Enhancer 3000 is a monitoring system that allows the user to monitor their electroporation
parameters to help optimize applications, troubleshoot, for recording purposes or simply for QC.

 

Can I use the Enhancer 3000 with any BTX Electroporator?
No. The monitor must be used on an electroporator with external outputs. It cannot be used
with the Hybrimune or the Agile Pulse systems.

   

BTX
Do you offer academic or institutional discounts?
Since our researchers work primarily in universities, we have kept our prices as low as possible.
Rather than inflate the price in order to discount to all, we have found that researchers would
rather have prices based on value. So, in effect, the discount is built into the price.

 

Does BTX offer on site application training?
Yes. BTX offers customized application specific trainings on site for a charge. Contact BTX
for a more information.

 

What does ECM stand for?
ECM stands for Electro Cell Manipulation. This is the process of manipulating cells using electrical
methods.

 

What does BTX stand for?
BTX stands for BioTechnology eXperimental Research.

 

How can I order your product if I am in another country?
Please see our BTX home page, at www.btxonline.com.

   

Where is BTX located?
Our address is BTX Harvard Apparatus 84 October Hill Rd.Holliston, MA 01746 USA

   

What is BTX’s operating hours?
BTX is open Monday through Friday from 8:30am EST to 5:00pm EST

     

WARRANTY & REPAIR FAQ’S:
How long is the BTX warranty on generators, accessories and electrodes?
The warranty on BTX generators and plate handlers is for a period of 2 years. For accessories
and electrodes, we offer a 90 day warranty period.

   

If I ordered something in error, can I return it?
If you ordered something in error, you can return it within 30 days. You may be charged a
15% restocking fee.

   

What if I ordered a BTX system and it doesn’t work for my application?
We always recommend speaking with someone in technical support before ordering a system.
If your recommended system does not work for your application, we ask that you work with
our technical support department either through optimization or troubleshooting prior to
returning the setup. If you are still unhappy with the result, you may return it for full credit
within 30 days.

   

My generator is under warranty and I believe it’s malfunctioning. How can I get it repaired?
Please contact technical support in order to determine if it is your generators that is malfunctioning
or some other factor causing issues. If it is determined that your generator is not functioning properly,
we will issue an RMA number (Returned Materials Authorization). You cannot return the generator
without this RMA number. If you attempt to return a unit for repair without an RMA number, the unit
will be returned to you as we cannot received it here without proper paperwork. You are responsible
for the cost of sending the generator to BTX in Holliston MA. Make sure that the unit is packed well,
preferably in its original casing to ensure no further damaged is caused in shipping. Once received,
BTX engineers will evaluate and repair your unit quickly. BTX will then send the unit back to you.

  

I dropped my 1 year old generator and it’s not working, does the warranty cover repairs?
No. The warranty covers manufacturing defects only.  

 

Can I send my system in for routine calibration?
Yes. BTX does offer a calibration service for a fee. Please contact BTX for a quotation.

   

How long does a repair take?
Once the unit is received in house, it is a first come first serve basis. Typical repairs take 1-2
weeks from date of receipt. Repairs can be expedited in certain situations.

   

Can I receive a loaner system while my generator is being repaired?
Yes. If your generator is under warranty, and you cannot be without a system, BTX will gladly
send you a loaner unit during the time that your unit is being repaired. Again, this service is
offered on a first come first serve basis as BTX has a small inventory of loaner units. If your
unit is not under warranty, you may still request a loaner unit, however warranty cases will
take priority. BTX must secure a PO for the unit prior to sending it out. 

 

I am looking for a service manual. Where can I get one?
BTX Does not provide service manuals. Due to the nature of these electrical units, we do
not recommend that anyone open these units and attempt to work on them. If a unit is
opened, this will void your warranty. BTX does not accept responsibility for any persons
who attempts to alter or service any BTX generator.

     

TECHNICAL ASSISTANCE
If I email your website for technical help, how long does it take to get a response?
The typical response time is 24 hours for any technical request. Any requests received Friday
afternoon after 5:00pm will be answered promptly on Monday morning.

 

Will BTX provide references if I ask?
We will do our best to provide you with any references that you require. We have a database
full of customers who are happy to share their experiences with you.

 

I am working with a BTX protocol that references a publication. Can I get a copy?
Yes. Simply provide the protocol number and we will do the rest. You can receive faxed,
emailed (PDF) or mailed copies.

 

I am looking for a user’s manual. Where can I get one?
User manual are sent out with each generator on CD. If you do not have the CD, please
feel free to download the manual from the BTX website.