Loading... Please wait...The Hybrimune™ System is an advanced electrofusion solution for fast, efficient cell fusion in hybridoma production, hybrid cell formation or dendritic-tumor cell fusions. The Hybrimune™ system includes an innovative fusion chamber design, proprietary Cytofusion® medium and sophisticated, tri-phasic electric field pulses that quickly position cells and disrupt cell membranes for maximum cell fusion efficiency with short cycle-times and minimal heating or turbulence for excellent cell viability.
The Hybrimune boasts a gradual increase in AC amplitude to compress the cells for maximal cell-cell contact, then the DC pulse is applied and the researcher has the option of doing multiple pulses in different voltage and duration if required, then a final AC waveform holds the cells in place and stabilizes the fusion as the force is gradually reduced. The waveform generator is fully-programmable for pulse parameter optimization to maximize efficiency and cell viability. A computer is required for the application software but is not included in the system.
Use of the AgilePulse HT system (formerly Cyto LVT-P) is subject to an annual license agreement between Cellectis bioresearch and the purchaser. Please contact Cellectis bioresearch cytopulse@cellectis.com for further details.
Use of the Hybrimune® device is subject to an annual license agreement between Cellectis bioresearch and the purchaser. Please contact Cellectis bioresearch cytopulse@cellectis.com for further details.
Use of the Agile Pulse In Vivo system (formerly the DermaVax device) is not authorized for any veterinary and human therapeutic uses. Contact Cellectis therapeutics contact@cellectis-therapeutics.com for such uses.
WAVEFORM SPECIFICATIONS
The Hybrimune™ Waveform Generator is programmed using the interface software. The Hybrimune™ waveform generator interface software must be installed on a local computer with these minimum specifications: Windows® 98 or higher, 2Mb free disk space, and at least one RS232 Serial Port. If only USB ports exist, then a USB-to-Serial adapter will be required, and should be installed first.
The following parameters are available:
|
|
Pulse Function |
|
Constant, linear, non-linear |
|
|
Pulse Amplitude |
|
100-1000 V |
|
|
Pulse Width Range |
|
20 – 1000 ms |
|
|
AC Start Peak Range |
|
5-75 Vs |
|
|
AC Stop Peak Range |
|
5-75 V |
|
|
AC Frequency |
|
0.2 to 2.0 MHz |
|
|
AC Duration |
|
0 to 60 sec |
FUSION CHAMBER SPECIFICATIONS
The optimization and production chambers have been engineered to have identical electrical characteristics to facilitate direct scale-up to production once pulse parameters have been optimized. In addition the small chamber has a transparent bottom to permit visualization of the cell alignment by inverted or regular microscope.
|
Parameter |
Optimization Chamber |
Production Chamber |
|
Volume |
2 ml |
9 ml |
|
Outer ID |
45.72 mm |
45.72 mm |
|
Inner OD |
38.10 mm |
38.10 mm |
|
Gap |
3.81 mm |
3.81 mm |
|
Well Height |
5 mm |
18 mm |
|
Inner/Outer Radius |
0.8333 |
0.8333 |
For reuse, the fusion chamber can be cleaned with NaOH, sterilization by EtOH, and Spor-Klenz® for spores and mycoplasma.
|
Catalog |
|
Description |
|
47-0300N |
|
Hybrimune System Includes: Hybrimune waveform generator, 2ml and 9ml coaxial chambers, BTXpress Cytofusion Medium C, user interface software, cables and manual. Requires Windows based laptop or PC (not included). |
|
Accessories |
|
|
|
47-0020 |
|
9ml Coaxial chamber for production |
|
|
|
|
|
47-0030 47-0302 |
|
2ml Coaxial chamber for optimization Chamber Cable |
|
|
|
|
|
47-0301 |
|
User Interface Application Software |
|
|
|
|
|
47-0001 |
|
BTXpress Cytofusion Medium C, 500ml volume |
BTX Monthly Tech Trends Articles
For further references regarding specific applications and optimization, please contact BTX Technical Support:
BTX-Division of Harvard Apparatus
84 October Hill Road
Holliston, MA 01746
Phone: 1-508-893-8999
Toll Free: 1-800-272-2775
Fax: 1-508-429-5732
Email: techsupport.btx@harvardapparatus.com
If outside the United States or Canada: call 508-893-8999 or
contact your nearest BTX Distributor
Lobito, A. et. al., 2011, Amer. Soc. For Bio. & Mole. Bio
Yu, X. et al., 2008, J Immunol Methods
Li, J, et al., 2006, PNAS
Trevor, K. et al., 2004, Cancer Immunology