Loading... Please wait...

Our Newsletter


ECM 830 High Throughput Electroporation System

  • ECM 830 & HT 200 Plate Handler
  • HT 100 & HT 200 Plate Handler
  • 96 well plate



The BTX® High Throughput (HT) System, offers a multi-well electroporation technology for processing multiple samples in seconds. Using the HT Multi-Well plates instead of traditional cuvettes, the researcher can transition from a single  cuvette to either a 96 well or 25 well electroporation plate by using one simple plate handler. This increases yields and the number of experiment runs in a single day. Experiments take seconds to run, allowing for quick and efficient optimization of the

electrical and biological parameters. Once optimized, samples are rapidly processed increasing yields and saving valuable time and money. The HT plate handler is compatible with the ECM 830 and some older ECM 830 generators (for more

details regarding compatibility of your ECM 830 systems please contact BTX Tech Support). The HT System is comprised of 3 components: The HT Multi-Well Plates, an HT Plate Handler and the BTX ECM 830 Generator.

APPLICATIONS

  • Mammalian Cells
  • Primary Cells
  • Stem Cells
  • siRNA Libraries

 

THE HT-100/HT-200

Standard Capabilities:

Power
100 to 240 VAC, 50/60 Hz, 15 W, 0.50 A fuse (2)
Voltage Range 0 to 3000V DC (Pulse)
Pulse Length Range 10 μsec to 10 sec
Pulse Number Range  1 to 99
Operating Temperature 5° to 40°C
Intended Use Indoor Use
Relative Humidity 20 to 80%
Maximum Altitude 2,000 m (6,562 ft)
Pollution Degree II
Insulation Degree CAT I
   
Physical Characteristics for Models HT-100 and HT-200:
 
Width x Depth x Height 23 x 21.5 x 14 cm (9.1 x 8.5 x 5.5 in)
Weight 4.8 Kg (10.6 lbs)

 

THE ECM® 830 GENERATOR

Standard Capabilities:

Display
Type: 20-character by 4-line liquid crystal display. LED backlit.
Power Source Voltage 100 to 240 Vac, 50 to 60 Hz,CAT II
Power Pulse: 500 W Idle: 150 W
Fusing T2.5 250 V
  
Environmental Characteristics:
 
Intended Use 10°C to + 40°C 
Cooling Convection through metal case 
Relative Humidity 90% relative humidity 
Altitude 2,000 m (operating) 
   
Mechanical Characteristics:
 
Footprint 12.5 x 12.25 x 5.5 in (31.75 x 3.12 x 13.97 cm) (W x D x H)
Weight 15 lbs (6.8 kg)
Controls Single rotary encoder with integrated  push button
   
Electrical Characteristics:
 
Voltage 5 to 500 Volts (LV mode)@1 Volt resolution 30 to 3000 Volts (HV mode)@5 Volts resolution (Voltage Delivery@5% accuracy and Voltage Monitoring@5.0% accuracy)

Order #     Product

45-0421    Includes ECM 830 Generator, 4 mm gap, 2 x 96-Well

                Plates, Plate Seals and HT-200 Plate Handler

45-0411    Includes ECM 830 Generator, 4 mm gap, 6 x 25-Well

                Plates, Plate Seals and HT-200 Plate Handler

45-0452    96-Well Disposable Electroporation Plates, 4 mm gap,

                250 μl, 1 plate

45-0450    96-Well Disposable Electroporation Plate, 2 mm gap,

                125 μl, 1 plate

45-0462    25-Well Disposable Electroporation Plate, 4 mm gap,

                250 μl, 1 plate

45-0466    25-Well Disposable Electroporation Plate, 2 mm gap,

                125 μl, 1 plate

45-0463    25-Well Disposable Electroporation Plate, 4 mm,

                250 μl, pkg. of 6

45-0467    25-Well Disposable Electroporation Plates, 2 mm,

                125 μl, pkg. of 6

45-0401    HT-200 Plate Handler, Automatic Column Switching

BTX Protocol Database

BTX Monthly Tech Trends Articles

The BTX Current

In Vivo Tutorials

Technical Specifications

 

For further references regarding specific applications and optimization, please contact BTX Technical Support:

 

BTX-Division of Harvard Apparatus

84 October Hill Road 

Holliston, MA 01746 

Phone: 1-508-893-8999

Toll Free: 1-800-272-2775

Fax: 1-508-429-5732

Email: techsupport.btx@harvardapparatus.com

 

If outside the United States or Canada: call 508-893-8999 or

contact your nearest BTX Distributor

Blackmore, M.G., et al., High content screening of cortical neurons identifies novel regulators of axon growth, 2010, Molecular and Cellular Neuroscience

Buchser, W. J. et. al., 96-Well electroporation method for transfection of mammalian central neurons, 2006, BioTechniques

Zhao, Y. et. al., High-Efficiency Transfection of Primary Human and Mouse T Lymphocytes Using RNA Electroporation, 2006, Molecular Therapy 



Find Similar Products by Category


Write your own product review

Product Reviews

This product hasn't received any reviews yet. Be the first to review this product!