The BTX® High Throughput (HT) System, offers multi-well electroporation technology for processing multiple samples in seconds. Using the HT Multi-Well plates instead of traditional cuvettes, the researcher can transition from a single cuvette to either a 96 well or 25 well electroporation by using one simple plate handler. This increases yields and the number of experiment runs in a single day. Experiments take seconds to run, allowing for quick and efficient optimization of the electrical and biological parameters. Once optimized, samples are rapidly processed increasing yields and saving valuable time and money. The HT plate handler is compatible with the ECM® 630 including older ECM® 630 generators. 


SPECIFICATIONS FOR THE HT-100/HT-200

Power 100 to 240 VAC, 50/60 Hz, 15 W, 0.50 A fuse (2)
Voltage Range 0 to 3000V DC (Pulse)
Pulse Length Range 10 μsec to 10 sec
Pulse Number Range 1 to 99
Operating Temperature 5° to 40°C
Intended Use Indoor Use
Relative Humidity 20 to 80%
Pulse Length Range 10 μsec to 10 sec
Maximum Altitude 2,000 m (6,562 ft)
Pollution Degree II
Insulation Degree CAT I
Width x Depth x Height 23 x 21.5 x 14 cm (9.1 x 8.5 x 5.5 in)
Weight 4.8 Kg (10.6 lbs)
   
  SPECIFICATIONS FOR THE ECM® 630 GENERATOR
Display Type  20-character by 4-line liquid crystal Display. LED backlit.
Power Source Voltage  100 to 240 Vac, 50 to 60 Hz, CAT II Power 500 W (Pulsed), 50 W (Idle) 
Fusing   2.5 A, T rating 250 V 
   
  ENVIRONMENTAL CHARACTERISTICS
Intended Use  Indoor use only 
Operating Temperature 10° C to + 40° C
Cooling Convection through metal case
Relative Humidity  60% 
Altitude 2,000 m (operating)
   

MECHANICAL CHARACTERISTICS

Footprint 12.5" x 12.25" x 5.5" (W x D x H)
Weight 13.6 lbs (6.2 kg)
Controls Single rotary encoder with integrated
Order # Product
45-0423 Includes ECM 630 Generator, 2 mm gap, 2 x 96-Well Plates, Plate Seals and HT-200 Plate Handler
45-0051 Includes ECM 630 Generator, 2 mm gap,6 x 25-Well Plates, Plate Seals and HT-200 Plate Handler
45-0452 96-Well Disposable Electroporation Plates, 4 mm gap, 250 μl, 1 plate
45-0450
96-Well Disposable Electroporation Plate, 2 mm gap, 125 μl, 1 plate
45-0462 25-Well Disposable Electroporation Plate, 4 mm gap, 250 μl, 1 plate
45-0466 25-Well Disposable Electroporation Plate, 2 mm gap, 125 μl, 1 plate
45-0463 25-Well Disposable Electroporation Plate, 4 mm, 250 μl, pkg. of 6
45-0467 25-Well Disposable Electroporation Plates, 2 mm, 125 μl, pkg. of 6
45-0400 HT-100 Plate Handler, Manual Column Switching
45-0401 HT-200 Plate Handler, Automatic Column Switching ECM® 630 High Throughput

BTX Protocol Database

BTX Monthly Tech Trends Articles

The BTX Current

In Vivo Tutorials

Technical Specifications

 

For further references regarding specific applications and optimization, please contact BTX Technical Support:

 

BTX-Division of Harvard Apparatus

84 October Hill Road 

Holliston, MA 01746 

Phone: 1-508-893-8999

Toll Free: 1-800-272-2775

Fax: 1-508-429-5732

Email: techsupport.btx@harvardapparatus.com

 

If outside the United States or Canada: call 508-893-8999 or

contact your nearest BTX Distributor

Colot, H.V. et. al., How to create gene knockouts in Neurospora



Find Similar Products by Category


Write your own product review

Product Reviews

This product hasn't received any reviews yet. Be the first to review this product!