Loading... Please wait...

Our Newsletter


ECM® 2001 Electroporation System

  • Image 1
  • Image 2
  • Safety Stand, Cuvettes and Cuvette Rack



FEATURES

  • Versatile Electro Cell Fusion &  Electroporation Instrument
  • Wide Range of Parameters

The ECM2001 EP System is designed for transfection of eukaryotic cells in suspension using electroporation cuvettes. The system comes complete with the ECM 2001 square wave DC generator, safety stand for cuvette electroporation, cuvette rack with 20 numbered positions and 10 each of the BTX Plus cuvettes in 1mm, 2mm and 4mm gap sizes, power cord and a CD with user manual. 

 This electroporation and electrofusion generator can also be used for cell fusion, in vivo or adherent cell electroporation by adding one of our specialty electrodes.  See our, Cell Fusion, Adherent Cell or In Vivo section for more details. 

AC Parameters (Alignment)
Proprietary nonsinusoidal wave shape 
Frequency 1 MHz
Voltage 0 – 75 V RMS (zero to peak)
Duration 0 – 99 sec
Post fusion AC 1/10 of pre fusion amplitude
Post fusion ramp 1 – 9 sec
Pause between AC/DC 50 μsec
   
DC Pulse Parameters (Fusion) (Electroporation)  
High Voltage Mode:  
Voltage 10 – 3000 V 
Pulse Length  1 – 99 μsec/ 1 μsec resolution 
Low Voltage Mode:   
Voltage   10 – 500 V 
Pulse Length  1 – 9 pulses 
Number of Pulses  0.01 – 0.99 msec/ 0.01 msec res 1 – 99 msec/ 1 msec res 
Catalog# Product Description
45-0011
ECM2001EP Electroporation System includes ECM 2001 Generator,
 Safety Stand 630B , Cuvettes 1 mm, 2 mm, 4 mm, pkg. of 30 
(10 each), Cuvette Rack 660
45-0207 630B Safety Stand for use with Electroporation Cuvettes
45-0208 660 Cuvette Rack with 20 numbered positions
45-0802 BTXpress Electroporation Buffer, 5ml
         
45-0124 610 Disposable Cuvettes Plus 1mm gap 90µl Sterile package of 50
45-0125 620 Disposable Cuvettes Plus 2mm gap 400µl Sterile package of 50
45-0126 640 Disposable Cuvettes Plus 4mm gap 800µl Sterile package of 50

BTX Protocol Database

BTX Monthly Tech Trends Articles

The BTX Current 

Technical Specifications

User Manual

For further references regarding specific applications and optimization, please contact BTX Technical Support:

BTX-Division of Harvard Apparatus

84 October Hill Road 

Holliston, MA 01746 

Phone: 1-508-893-8999

Toll Free: 1-800-272-2775

Fax: 1-508-429-5732

Email: techsupport.btx@harvardapparatus.com

If outside the United States or Canada: call 508-893-8999 or

contact your nearest BTX Distributor

Not available.


Find Similar Products by Category


Write your own product review

Product Reviews

This product hasn't received any reviews yet. Be the first to review this product!